BWRMT - 841 5580;EKTACOLOR RA DEVELOPER REPLENISHR RT;PT.C;KAN448408
- MSDS: BWRMT
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 841 5580;EKTACOLOR RA DEVELOPER REPLENISHR RT;PT.C;KAN448408
- National Stock Number: 6750-01-384-7889
Product Identification
Product ID:841 5580;EKTACOLOR RA DEVELOPER REPLENISHR RT;PT.C;KAN448408
MSDS Date:11/02/1994
FSC:6750
NIIN:01-384-7889
Kit Part:Y
MSDS Number: BWRMT
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 716-722-5151
Cage: 19139
Contractor
Telephone: 800-828-6203
Cage: 5K871
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 60-70%
POTASSIUM CARBONATE
CAS: 584-08-7
RTECS: TS7750000
Fraction By Weight: 25-35%
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 1-5%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
POTASSIUM BROMIDE
CAS: 7758-02-3
RTECS: TS7650000
Fraction By Weight: <1%
PHOSPHONIC ACID,(1-HYDROXYETHYLIDENE)DI-
CAS: 2809-21-4
RTECS: SZ8562100
Fraction By Weight: <1%
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXPECTED TO BE A LOW HAZARD FOR
RECOMMENDED HANDLING.EYES:MAY CAUSE BURNS.SKIN:MAY CAUSE
IRRITATION.INGEST:MAY CAUSE GI TRACT BURNS.
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:EYES/SKIN/INGEST:IRRITATION AND BURNS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN:REMOVE CONTAMINATED CLOTHING;WASH WITH SOAP AND
WATER.EYES:FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL
ATTENTION.INHAL:REMOVE TO FRESH AIR.GIVE OXYGEN OR ARTIFICIAL
RESPIRATION IF NEEDED.INGEST: DO NOT INDUCE VOMITING.GET PROMPT
QUALIFIED MEDICAL ATTENTION.IF CONSCIOUS,GIVE 1-2 GLASSES OF W
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. FLUSH TO
SEWER WITH LARGE AMOUNTS OF WATER. OTHERWISE, ABSORB SPILL WITH
VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN A CONTAINER FOR
CHEMICAL WASTE. CLEAN SUR FACE THOROUGHLY TO REMOVE CONTAMINATION.
Neutralizing Agent:MAY REQUIRE NEUTRALIZATION IF PH <2.0 OR >12.5
BEFORE FLUSHING TO SEWER.
Handling
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. KEEP
FROM INCOMPATIBLE SUBSTANCES.
Other Precautions:KEEP FROM CONTACT WITH OXIDIZING MATERIALS.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE USED (TYPICALLY 10 AIR
CHANGES PER HOUR). MATCH RATE TO CONDITIONS.
Protective Gloves:WEAR IMPERVIOUS GLOVES.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:B1
Boiling Pt:>100.C, 212.F
B.P. Text:>212F,>100C
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.37
pH:>13
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID;COLORLESS;ODORLESS.
Percent Volatiles by Volume:60-70
Stability
Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.